Shenzhen Darui Bo Electronics Co., Ltd.
Central Lighting Technology Co., Ltd.
TEL: 13421364554
Products
Professional development, design, customization, production
Products Products
Products / Products
Published: 2017 - 07 - 15
Directional power meters are used to measure power and reflection under operational conditions. They are connected between source and load and measure the power flow in both directions. The power applied to the load and the reflection can thus be measured. Typical applications are in installation, maintenance and monitoring of amplifiers, transmitters, antennas and RF/microwave generators in industrial and medical fields.
Published: 2017 - 07 - 15
To support a wide range of test requirements, the GSS6300 can be remotely controlled via standard interfaces such as IEEE-488, USB or RS-232. In addition, Spirent SimCHAN software can be used to implement real-time user control of the GSS6300, making it an accurate laboratory GPS / SBAS, GLONASS and / or Galileo test equipment.
Published: 2017 - 07 - 15
Customers looking for a general purpose spectrum analyzer will appreciate the flexibility of the ESA spectrum analyzer that can be used for a wide range of applications from aerospace and defense to the manufacturing line. Browse the ESA Brochure.Customers who wish to take advantage of the ESA flexibility but who need a faster analyzer for the manufacturing line, or connectivity to LAN/USB in addition to GPIB, or want to do in depth signal analysis with 89600 VSA software will benefit from the new EXA signal analyzer. The EXA signal analyzer now comes standard with many of the ESAs optional features and yet offers more applications than the ESA. Migrate from ESA to EXA.
Contact
Tel: 13421364554
Email:
daruibo@daruibo,com
daruibo@daruibo,com
daruibo@daruibo,com
Add: Longhua District, Guangdong Province, the people show white Shilong Yi Fang Tiande Village East Building, Room 1412
Rohde & Schwarz NRT-Z5
product name:

Rohde & Schwarz NRT-Z5

Listing date: 2017-07-15

         Directional power meters are used to measure power and reflection under operational conditions. They are connected between source and load and measure the power flow in both directions. The power applied to the load and the reflection can thus be measured. Typical applications are in installation, maintenance and monitoring of amplifiers, transmitters, antennas and RF/microwave generators in industrial and medical fields.
      

 

 

  • Power measurement on transmitters, amplifiers, industrial RF and microwave generators

  • Simultaneous display of power and reflection

  • Measurement of average power irrespective of modulation mode

  • Measurement of peak power, crest factor and average burst power

  • Compatible with all main digital standards, for example, GSM/EDGE, 3GPP (W-/TD-CDMA), CDMA (IS-95), CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB, DVB-T

  • Intelligent sensors: simply plug in and go

  • IEC625 (IEEE488) bus and RS-232 interface

  • Digital interface between sensor and basic unit

  • Direct connection of sensor to a PCR&S®NRT base unit specifications:

  • Frequency range: 200 kHz to 4 GHz

  • Power measurement range: 0.7 mW to 2 kW

  • Measurement inputs

    • For R&S®NRT-Z sensors: 1 to 3 (4), one active one input on front panel, two additional inputs on rear panel (option R&S®NRT-B2)

    • For R&S®NAP-Z sensors: one input on rear panel (option R&S®NRT-B1)

  • Measurement functions

    • Power: Forward power and power absorbed by the load in W, dBm, dB or % (dB and % referenced to measured value or reference value)

    • Power parameters: Average power, average burst power, peak envelope power, peak-to-average ratio (crest factor), complementary cumulative distribution function

    • Reflection: SWR, return loss, reflection coefficient, reverse-to-forward power ratio in %, reverse power

  • Frequency response correction: Upon input of RF frequency, the stored correction factors of the power sensor being taken into account; for R&S®NAP-Z sensors the R&S®NRT base unit offers memory for 3 sets of calibration factors

  • Zero adjustment: Selectable with RF power switched off, duration approximately 5 s

  • LCD display

    • Digital: Simultaneous indication of power, reflection, and carrier frequency (input value)

    • Resolution: HIGH is 4½ digits (0.001 dB), LOW is 3½ digits (0.01 dB)

    • Analog: Two 50-element bargraphs for indication of power and reflection with selectable or pre-defined scale-end values

  • Averaging: Automatic, depending on selected resolution and sensor characteristics

  • Max/Min: Display of current maximum, minimum, or difference value (Max-Min) for the selected measurement functions

  • Remote control: To SCPI-1995.0 command set

    • IEC / IEEE bus: To IEC 625 (IEEE 488); interface functions SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT1

    • Serial interface 9-pin: D-Sub connector to EIA-232E; 1200 / 2400 / 4800 / 9600 baud; RTS/CTS or XON/XOFF handshake selectable

  • AUX connector: BNC connector as signaling output or trigger input (TTL)

  • Beeper: For SWR monitoring (power and SWR threshold selectable) and acoustic echoing of keystrokes

  • Setups: Last setting, default setting and up to four user-defined instrument settings


Description / Case More>>
Copyright ©2009 - 2019Shenzhen Darui Bo Electronics Co., Ltd.
犀牛云提供企业云服务
地址:广东省深圳市龙华新区白石龙逸秀新村东方天德大厦1412
TEl:13421364554
Fax:+86 0755-2788 8009
Zip Code:330520
X
1

QQ设置

  • cindy
3

SKYPE 设置

4

阿里旺旺设置

  • 旺旺客服maygliao
6

二维码名称

Unfolded