Directional power meters are used to measure power and reflection under operational conditions. They are connected between source and load and measure the power flow in both directions. The power applied to the load and the reflection can thus be measured. Typical applications are in installation, maintenance and monitoring of amplifiers, transmitters, antennas and RF/microwave generators in industrial and medical fields.
Published: 2017 - 07 - 15
To support a wide range of test requirements, the GSS6300 can be remotely controlled via standard interfaces such as IEEE-488, USB or RS-232. In addition, Spirent SimCHAN software can be used to implement real-time user control of the GSS6300, making it an accurate laboratory GPS / SBAS, GLONASS and / or Galileo test equipment.
Published: 2017 - 07 - 15
Customers looking for a general purpose spectrum analyzer will appreciate the flexibility of the ESA spectrum analyzer that can be used for a wide range of applications from aerospace and defense to the manufacturing line. Browse the ESA Brochure.Customers who wish to take advantage of the ESA flexibility but who need a faster analyzer for the manufacturing line, or connectivity to LAN/USB in addition to GPIB, or want to do in depth signal analysis with 89600 VSA software will benefit from the new EXA signal analyzer. The EXA signal analyzer now comes standard with many of the ESAs optional features and yet offers more applications than the ESA. Migrate from ESA to EXA.
Contact
Tel: 13421364554
Email:
daruibo@daruibo,com
daruibo@daruibo,com
daruibo@daruibo,com
Add: Longhua District, Guangdong Province, the people show white Shilong Yi Fang Tiande Village East Building, Room 1412
R&S®FSU Spectrum Analyzer
product name:

R&S®FSU Spectrum Analyzer

Listing date: 2019-09-23

Brief Description

The R&S®FSU is a high-performance spectrum analyzer with outstanding performance in phase noise, dynamic range and measurement accuracy that meets any challenge in RF analysis – in aerospace and defense or for general microwave applications up to 67 GHz.

To handle the wide variety of measurement tasks in product development, an instrument must offer ample functionality and excellent performance in all areas of interest. The R&S®FSU fully meets these requirements.

Its wide dynamic range makes the R&S®FSU an ideal tool for base station development and testing. That plus the excellent characteristics already incorporated in the standard model, e.g.

Key Facts

  • 3.6/8/26/43/46/50/67 GHz

  • TOI > 20 dBm, typ. +25 dBm

  • 1 dB compression: +13 dBm (0 dB RF attenuation)

  • Displayed average noise level: –152 dBm at 2 GHz; –148 dBm at 26 GHz (1 Hz bandwidth)

  • Typ. 77 dB ACLR for 3GPP, typ. 84 dB with noise correction

  • Phase noise: typ. –160 dBc (1 Hz) at 10 MHz carrier offset

  • Noise correction

  • Features & Benefits

    • Shorter development cycles through versatile functions, wide dynamic range and performance

      • Full choice of detectors

      • Versatile resolution filters

      • Full range of analysis functions

      • High dynamic range

    • Innovative solutions through customized options

      • Measuring frequency deviation after settling

      • Power measurement

      • Scalar network analysis with wide dynamic range

    • Spectrum analysis up to 67 GHz/110 GHz

      • Direct frequency range up to 67 GHz

      • Easy expansion of the frequency range to 110 GHz with external mixers from 

        Rohde & Schwarz
      • Support of external mixers up to 1 THz

    • High throughput in production

      • Fast time domain power measurement

      • List mode: combined measurement of various parameters with a single command

      • Up to 70 measurements/s in zero span via IEC/IEEE bus, including trace data transfer

      • Fast frequency counter: 0.1 Hz resolution for a measurement time of 

      • Short test cycles, high throughput

      • 859x/8566-compatible IEC/IEEE bus command set

      • High measurement speed

  • Specifications


  • R&S®FSU3R&S®FSU8R&S®FSU26R&S®FSU43
    Frequency range20 Hz to 3.6 GHz20 Hz to 8 GHz20 Hz to 26.5 GHz20 Hz to 43 GHz
    Reference frequencyaging: 1 x 10 –7/year, with R&S®FSU-B4 option: 3 x 10 –8/year
    Spectral purity
    Phase noisetyp. –133 dBc (1 Hz) at 640 MHz in 10 kHz from carrier
    Sweep time
    Span ≥10 Hz2.5 ms to 16 000 s
    Span 0 Hz (zero span)1 μs to 16 000 s
    Resolution bandwidth10 Hz to 50 MHz (R&S®FSU43: 10 Hz to 10 MHz), FFT filter: 1 Hz to 30 kHz, channel filter, EMI bandwidth
    Video bandwidth1 Hz to 10 MHz
    Display rangedisplayed average noise level to +30 dBm
    Displayed average noise level (1 Hz RBW)
    1 GHztyp. –158 dBmtyp. –158 dBmtyp. –156 dBmtyp. –156 dBm
    7 GHztyp. –154 dBmtyp. –156 dBmtyp. –153 dBm
    13 GHztyp. –153 dBmtyp. –153 dBm
    26 GHztyp. –148 dBm
    40 GHztyp. –143 dBm
    Displayed averagenoise level with preamplifier ON 
    (R&S®FSU-B25), 1 GHz, 1 Hz RBW
    < –162 dBm< –162 dBm< –162 dBm< –162 dBm
    Displayed averagenoise level with preamplifier ON 
    (R&S®FSU-B24), 26 GHz, 10 Hz RBW
    typ. –166 dBmtyp. –166 dBm
    Trace detectorsMax Peak, Min Peak, Auto Peak, Sample, RMS, Average, Quasi Peak, CISPR-AV, CISPR-RMS
    Total measurement error, f < 3.6 GHz0.3 dB
    Display linearity0.1 dB (0 dB to –70 dB)

    R&S®FSU46R&S®FSU50R&S®FSU67
    Frequency range20 Hz to 46 GHz20 Hz to 50 GHz20 Hz to 67 GHz
    Reference frequencyaging: 1 x 10 –7/year, with R&S®FSU-B4 option: 3 x 10 –8/year
    Spectral purity
    Phase noisetyp. –133 dBc (1 Hz) at 640 MHz in 10 kHz from carrier
    Sweep time
    Span ≥ 10 Hz2.5 ms to 16 000 s
    Span 0 Hz (zero span)1 μs to 16 000 s
    Resolution bandwidth10 Hz to 50 MHz (R&S®FSU43: 10 Hz to 10 MHz), FFT filter: 1 Hz to 30 kHz, channel filter, EMI bandwidth
    Video bandwidth1 Hz to 10 MHz
    Display rangedisplayed average noise level to +30 dBm
    Displayed average noise level (1 Hz RBW)
    1 GHztyp. –156 dBmtyp. –156 dBmtyp. –152 dBm
    7 GHztyp. –153 dBmtyp. –153 dBmtyp. –148 dBm
    13 GHztyp. –153 dBmtyp. –153 dBmtyp. –148 dBm
    26 GHztyp. –148 dBmtyp. –148 dBmtyp. –142 dBm
    40 GHztyp. –143 dBmtyp. –136 dBmtyp. –142 dBm
    50 GHztyp. –131 dBmtyp. –140 dBm
    60 GHztyp. –132 dBm
    Displayed averagenoise level with preamplifier ON 
    (R&S®FSU-B25), 1 GHz, 1 Hz RBW
    < –162 dBm< –162 dBm
    Displayed averagenoise level with preamplifier ON 
    (R&S®FSU-B24), 26 GHz, 10 Hz RBW
    typ. –166 dBmtyp. –166 dBm
    Trace detectorsMax Peak, Min Peak, Auto Peak, Sample, RMS, Average, Quasi Peak, CISPR-AV, CISPR-RMS
    Total measurement error, f < 3.6 GHz0.3 dB
    Display linearity0.1 dB (0 dB to –70 dB)